| OFVS10 and OFVS25 Over Fascia Ventilating System for tiled roofs to provide: 1. Eaves level roof void ventilator. 2. Hinged underlay support. 3. Bird excluder. 4. Tile clipping (clip extra). 5. Insect Inhibitor. 6. Drip into gutter. OFVS10/L and OFVS25/L Over Fascia Ventilating System for slate roofs (including interlocking slates and plain tiles) to provide: 1. Eaves level roof void ventilator. 2. Hinged underlay support. 3. Insect Inhibitor. 4. Drip into gutter. Complies with the requirements of Part F2 of the Building Regulations 1995 and the recommendations of BS 5250: 1989 for eaves level ventilation in slate and tiled roofs over 15° pitch. |